Transformer

Your Professional Transformer Supplier

 

Zhejiang GangHeng Electric Co., Ltd., founded in 2004, is a manufacturer of high- and low-voltage switchgear and transformers. Our team covers R&D, production, and quality control, with stable technical staff and experienced engineers. The factory is located in Jiangshan City, Zhejiang, in a major transport hub that supports fast delivery. We operate modern production lines with CNC punching, CNC bending, and laser cutting machines, along with dedicated copper busbar and testing equipment.

 

 
First 12 Last 1/2
 
Why choose us

Certifications

We are ISO9001、 ISO14001 、OHSAS18001、CQC product certification, high-voltage cabinet type test report and various patent certificates, etc.

Production Market

Our The products are sold to various provinces across the country as well as to countries such as Iran, Kyrgyzstan, Zimbabwe, and Tanzania

Custom Solutions

We offer tailored solutions for OEM/ODM projects. Whether adapting our switchgear or transformers for specific needs, our CNC production equipment ensures precise customization.

 

After-Sales Support & Warranty

We stand behind our products with a 1-year free warranty and 5-year latent defect coverage, ensuring long-term reliability. In case of technical issues, we provide on-site support and take full responsibility for any technical guidance errors, giving customers peace of mind throughout the product's lifecycle.

 

SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry Transformer​
 

SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry Transformer​ is a critical component in medium to large-scale electrical distribution systems, widely used in commercial buildings, industrial facilities, and infrastructure projects. Unlike oil-filled transformers, dry-type units use air as the cooling medium and are designed for indoor installation, offering enhanced safety and reduced maintenance.

 

Rated High Voltage

10kV

Rated Low Voltage

0.4kV

Rated Capacity

1250kVA

Connection Symbol

Dyn11

No-Load Loss

≤1.2kW

Load Loss (120% load)

≤6.8kW

Cooling Method

AN/AF (Forced Air Cooling)

Insulation Level

170kV/3s

Protection Class

IP30

 

Advantages of Type of SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry

Fire Safety

Non-flammable design eliminates fire hazards associated with oil-filled units, making them suitable for densely populated or enclosed spaces.

01

Low Maintenance

No oil to monitor or replace reduces operational costs and downtime.

02

Environmental Safety

No risk of oil leaks or soil contamination ensures compliance with environmental regulations.

03

Compact & Space-Efficient

Ideal for installation in electrical rooms, basements, or multi-tenant buildings with limited space.

04

Voltage Stabilit

Provides consistent voltage output, protecting sensitive equipment from fluctuations and surges.

05

 

Type of SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry Transformer
 
SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry Transformer​

Single-Phase Dry Transformers
Designed for single-phase AC power systems, these transformers are typically used in low to moderate power applications where three-phase supply is not available or necessary.

 

Three-Phase Dry Transformers
Built to operate on three-phase power systems, these transformers efficiently handle balanced loads and are standard in industrial and large commercial installations requiring 1250 KVA capacity.

 

Autotransformers
Unlike isolation transformers, autotransformers use a single winding that serves as both primary and secondary, allowing for voltage step-up or step-down with high efficiency and reduced size.

 

Isolation Transformers
These transformers feature separate primary and secondary windings, providing complete electrical isolation. This design enhances safety and power quality by blocking DC components and suppressing harmonics.

 

Dual-Voltage Dry Transformers
Engineered with multiple tap settings or dual windings, these transformers support two different input or output voltages, offering flexibility in regions with inconsistent grid standards or multinational operations.

 

Applications of SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry

Manufacturing

Powering motors and production lines,Stable voltage under high load, reduced downtime

01

Data Centers

Isolation and clean power supply,Protection against surges and EMI, enhanced uptime

02

Commercial Real Estate

Main distribution for HVAC, lighting, elevators Space-saving, fire-safe, efficient zoning

03

Oil & Gas

Control systems and instrumentation power,No fire risk, noise isolation, chemical resistance

04

Mining

Heavy equipment voltage control,Durability in harsh environments, no oil leaks

05

 

Core Technical Specifications of SCB14-Nx2 1250kVA 10kV Smart Forced Air Cooling Dry

Rated Capacity: 1250 KVA – capable of supporting heavy-duty electrical loads in industrial plants, data centers, and large commercial buildings.

 

Primary Voltage: Configurable up to 400V (or higher upon specification), ensuring compatibility with medium-voltage power supply systems.

 

Secondary Voltage: Standard output of 240V, ideal for powering auxiliary systems, lighting, and HVAC equipment.

 

Frequency: Operates at 50/60 Hz (standard), not "up to ten hertz" — this correction ensures accuracy, as power transformers are designed for grid-standard frequencies.

Winding Material

Available in copper or aluminum windings. Copper offers superior conductivity and longevity; aluminum provides a cost-effective, lightweight alternative with slightly lower efficiency.

Insulation Class

Typically rated at Class F (155°C) or Class H (180°C), allowing safe operation under high thermal stress.

Cooling Method

Natural Air Cooling (AN) or Forced Air Cooling (AF). As a dry-type transformer, it uses air instead of oil, eliminating fire hazards and environmental contamination risks.

 

Step-by-Step Installation Guidelines

 

Foundation Requirements: Construct a solid, level, and textured concrete base capable of supporting the transformer’s full weight (typically 3,000–5,000 kg). This minimizes vibration and prevents structural settling.

 

Clearance and Ventilation: Maintain minimum clearances as per IEC 60076 or IEEE C57 standards—usually 1 meter on all sides—to ensure adequate airflow and cooling.

 

Electrical Connections: All wiring must be performed by licensed electricians using properly sized conductors and torque-rated lugs. Phase rotation and grounding must be verified before energizing.

 

Grounding: Bond the transformer frame to the facility’s grounding system using low-impedance cables to ensure personnel safety and surge protection.

 

Pre-Energization Check: Inspect for loose connections, foreign objects, and insulation integrity. Perform a megger test to confirm insulation resistance (>1000 MΩ recommended).

image003

 

Maintenance and Repair
 

Routine Inspection (Quarterly)

Visually check for signs of overheating (discoloration, insulation cracking), loose hardware, or rodent infestation. Look for corona discharge or arcing marks in high-humidity environments.

Cleaning (Biannual)

Use dry compressed air (max 30 psi) to remove dust and debris from windings and cooling ducts. Avoid water or solvents that could damage insulation.

Connection Tightening (Annual)

Re-torque all electrical and mechanical connections to manufacturer specifications to prevent resistance heating and energy loss.

Thermal Monitoring (Continuous)

Install built-in temperature sensors (RTDs or thermocouples) to monitor winding hot-spot temperatures. Alarms should trigger above 130°C (Class F) or 150°C (Class H).

Insulation Resistance Testing (Annual)

Perform a Megger test (1000V or 5000V DC) to assess insulation health. A reading below 100 MΩ may indicate moisture ingress or aging.

Thermographic Scanning (Biannual)

Use infrared cameras to detect hotspots in connections or windings, enabling predictive maintenance.

 

 

Certificates

productcate-558-699
productcate-558-699
 

FAQ

 

Q: What's the payment terms?

A: We accept T/T, L/C,Western Union, PayPal, etc.

Q: How long is the delivery time?

A: Generally it is 20-30 days, it depends on the order quantity.

Q: What is the standard of package?

A: Export standard package or special package according to customer's requirement.

Q: What is the MOQ?

A: The MOQ=1 unit. It would be great if you can provide technical drawing and technical specification document. If not, you can contact us for further communication.

Q: How long is the guarantee?

A: We offer 24 months(2 years) guarantee. The key parts over 30 years.

As one of the most reliable transformer manufacturers and suppliers in China, we cover all costs, risks, and your direct expenses. Please feel free to buy high quality transformer at competitive price from our factory. Customized orders are welcome.