Water Treatment & Desalination Switchgear Solutions

Water Treatment & Desalination Switchgear Solutions

 

 

page-1-1

Seawater desalination plants, municipal water treatment facilities, and wastewater treatment plants operate in some of the most electrically demanding environments in the utility sector - corrosive salt-laden air, continuous high-power pumping loads, and zero tolerance for supply interruption to intake, RO, and lift-station pumps. Zhejiang Gangheng Electric has manufactured HV, MV and LV switchgear since 2004, supplying power distribution equipment for seawater reverse osmosis (SWRO) plants, independent water & power producer (IWPP) projects, municipal water treatment works, and wastewater treatment facilities across the Middle East, Africa, and Asia. Our equipment is built to IEC standards, corrosion-rated for coastal and chemically aggressive environments, and backed by committed delivery schedules aligned to plant commissioning timelines.,

Send Inquiry

 

Switchgear & Power Distribution Products For Water Treatment & Desalination Facilities

 

 

Power distribution at desalination and water treatment plants spans intake pump stations, high-pressure RO pump motor loads, chemical dosing systems, and outfall/lift-station pumping - typically from a 10kV or 35kV main receiving substation down through 0.4kV motor control at each process area. Gangheng supplies the full HV/MV/LV equipment range for plant main substations, RO train switchrooms, and remote lift-station/pump-house locations, fully configurable to project voltage and local grid/utility standards.

 

High & Medium Voltage Switchgear - 12kV & 40.5kV

KYN28A-12 Indoor Metal-Clad Moveable Switchgear (12kV)

The standard choice for 10kV incoming panels and high-pressure RO pump motor feeder distribution at desalination plant main substations. Supports vacuum circuit breakers and microprocessor-based protection relays for automatic fault isolation of large motor loads. Five-prevention mechanical interlock system supports strict access control requirements typical of water utility operators.

KYN61-40.5 Armored Removable Switchgear (40.5kV)

Engineered for 35kV main receiving substations at large-scale SWRO and IWPP desalination complexes. Designed for high short-circuit withstand (up to 40kA) and internal arc fault protection, compatible with the bulk power entry requirements of large intake and high-pressure pump station loads.

HXGN / XGN2-10 Ring Main Units (10kV)

Compact ring-network switchgear for looped 10kV distribution between distributed pump stations, lift stations, and chemical dosing buildings spread across a large treatment plant or pipeline corridor - common in municipal water and wastewater network layouts.

 

page-1200-800
 
page-437-291
 
page-1200-800
 

 

Low Voltage Switchgear & MCC - 0.4kV / 380V

MNS & GCS Series Low Voltage Withdrawable Switchgear

Configured as Motor Control Centers (MCC) for continuous-duty intake pumps, high-pressure RO feed pumps, and dosing pump loads. Fully withdrawable drawer modules support hot-swap under power - a faulty pump feeder can be isolated and replaced without de-energising the main busbar, critical for plants with no permitted supply interruption to intake or outfall pumping.

GGD Fixed Low-Voltage Switchgear

A robust fixed-type distribution cabinet suited to auxiliary power distribution in pump houses and lift-station buildings where structural durability under corrosive, humid duty cycles takes priority over modular flexibility.

 

Learn More About Low Voltage Switchgear →

 

page-1200-800
 
page-1200-800
 
page-1200-800
 

 

Dry-Type Transformers & Prefabricated Compact Substations

 

1

For indoor plant substation applications, Gangheng supplies dry-type transformers eliminating oil leakage risk for installations near process water and chemical storage areas. Prefabricated compact substations integrating HV switchgear, transformer, and LV distribution in a single factory-assembled enclosure are available for rapid deployment at remote intake pump stations, lift stations, or expanded treatment trains - reducing civil construction time and on-site cabling at dispersed water infrastructure sites.

 

Learn More About Compact Substations →

 

 

Configured for Water Treatment & Desalination Environments

 

Standard switchgear is not adequate for the salt-laden, humid, and chemically corrosive conditions found at desalination and water treatment facilities. Gangheng equipment for water sector applications is specifically configured for:

01/

Corrosion-Resistant Enclosure Construction

Enclosures finished with epoxy anti-corrosion coatings or hot-dip galvanised treatment rated for C4/C5-M corrosion category environments. Stainless steel (SS304 / SS316L) enclosure options standard for coastal SWRO intake areas and chemical dosing buildings exposed to salt spray or chlorine/chemical vapour.

02/

High Enclosure Protection Ratings

IP54 enclosure rating standard for indoor pump-house switchrooms; IP65 available and commonly specified for outdoor lift stations, intake structures, and wastewater treatment plant equipment exposed to washdown, humidity, or hydrogen sulphide (H₂S) corrosive gas.

03/

Continuous-Duty Motor Load Support

High short-circuit withstand busbars and current-limiting circuit breakers for reliable fault clearing under large intake, RO high-pressure, and lift-station pump motor loads. Zone selective interlocking (ZSI) ensures only the faulted pump feeder trips, keeping remaining process pumps in continuous operation.

04/

Remote Site Monitoring & Diagnostics

Intake structures, lift stations, and outfall pump houses are frequently located away from the main plant control room. Switchgear equipped with intelligent I/O modules and 4G/5G DTU uploads breaker status and fault data to SCADA, supporting remote operation for dispersed water infrastructure assets.

 
 

05/ Modular, Quick-Replacement Design

Standardised functional units allow a faulted feeder module to be fully withdrawn and replaced without de-energising the main plant supply - recovery time reduced from hours to minutes, protecting continuous intake and outfall pumping operations.

page-1200-800

 

 

 

 

Application Scenarios in Water Treatment & Desalination

 
01/

Seawater Reverse Osmosis (SWRO) & IWPP Plant Main Substations

Large-scale desalination and independent water & power producer (IWPP) projects across the Gulf region require main receiving substations capable of supplying continuous, high-power intake and high-pressure RO feed pump loads. KYN61-40.5 serves as the 35kV incoming panel; KYN28A-12 handles 10kV feeder distribution to RO train motor control centers. Protection relay coordination and full FAT documentation provided for plant owner and grid operator acceptance.

02/

Municipal Water Treatment Plant Distribution

Conventional water treatment works - coagulation, filtration, and clear-water pumping stages - require dependable MV/LV distribution across multiple process buildings. GH configures HV switchgear with LV distribution cabinets and dry-type transformers as integrated substation packages sized to each treatment stage's motor and utility load.

03/

Wastewater Treatment & Lift Station Pumping

Wastewater treatment plants and network lift stations present corrosive hydrogen sulphide (H₂S) gas exposure that degrades standard steel enclosures within months. GH supplies stainless steel (SS304/SS316L) IP65 switchgear for aeration, sludge handling, and lift-station pump control, commonly specified for World Bank and African Development Bank-funded water and sanitation infrastructure projects.

04/

Intake Pump Stations & Outfall Structures

Seawater intake and outfall pump structures at coastal desalination plants require corrosion-rated, high-protection switchgear capable of continuous operation in direct salt-spray exposure, frequently at sites remote from the main plant control building.

 
page-800-531
05/ Water Network Expansion & Distribution Upgrades

 

Rapid urban growth across the Middle East and Africa is driving continuous expansion of desalination capacity and water/wastewater network coverage. GH specialises in capacity upgrade projects for operating plants - engineering equipment solutions that can be installed within available shutdown windows, minimising supply interruption to municipal customers.

 

 

 

Why Water Utility & Desalination Project Teams Specify Gangheng

 
page-600-800
 

Committed Delivery Against Project Milestones

Desalination and water treatment plant commissioning schedules are fixed by concession agreements, EPC contract milestones, and municipal supply commitments. We provide contractual delivery commitments:

Order Value

Delivery Lead Time

USD $300,000

30 days

USD $700,000

45 days

USD $1,500,000

60 days

 

Complete HV-to-LV Equipment Package from a Single Supplier

A single equipment source for HV switchgear, LV distribution, dry-type transformers, and prefabricated substations simplifies procurement for dispersed water infrastructure sites (intake, main plant, lift stations), reduces inter-supplier interface risk, and provides a single point of technical responsibility.

page-600-800

 

Explore GH in Virtual Reality

 

 

 

 

Technical Specifications at a Glance

 

Parameter

Gangheng Standard

Voltage Range

0.4kV LV · 12kV MV · 40.5kV MV

Primary Standards

IEC 62271 / ANSI C37 / BS EN / GB/T (all configurable)

Quality Certifications

ISO 9001 · ISO 14001 · OHSAS 18001 · CQC

Enclosure Protection

IP4X standard; IP54 / IP65 available

Enclosure Material

Al-Zn coated steel; hot-dip galvanised; SS304 / SS316L options

Anti-Corrosion Rating

C4 / C5-M coating available

Short-Circuit Withstand

Up to 40kA (model-dependent; confirm per project SLD)

Arc Flash Protection

Type-tested internal arc per IEC 62271-200

Communication Protocol

IEC 61850, Modbus RTU, RS485 (relay-dependent)

Transformer Type

Dry-type (indoor, fire-safe); Oil-immersed (outdoor)

Customisation

OEM/ODM; non-standard dimensions; component-level options

 

Frequently Asked Questions

 

 

Q: Does Gangheng supply switchgear suitable for coastal desalination plant environments with salt-spray exposure?

A: Yes. Our standard offering for coastal and desalination applications includes stainless steel (SS304/SS316L) enclosures, C4/C5-M anti-corrosion coatings, and IP65 protection ratings, engineered specifically for continuous salt-spray exposure at intake structures and outdoor pump stations.

Q: Can your switchgear handle the corrosive hydrogen sulphide (H₂S) environment typical of wastewater treatment plants?

A: Yes. We supply stainless steel double-door enclosures with potted control circuits and conformal-coated circuit boards, a configuration widely specified for wastewater treatment plants and lift stations where H₂S gas corrodes standard steel enclosures within months.

Q: Can your equipment meet IEC or ANSI standards required by international EPC contractors on desalination/IWPP projects?

A: Yes. Our standard production follows China GB/T specifications, and all equipment can be fully re-engineered to IEC 62271, ANSI/IEEE C37, or BS EN standards to match your project's technical specification, protection relay settings, and documentation requirements.

Q: Do you supply switchgear for remote intake pump stations or lift stations with limited site access?

A: Yes. Our switchgear can be equipped with 4G/5G DTU communication modules for remote SCADA monitoring and fault diagnostics, and prefabricated compact substations are available to minimise on-site civil and cabling work at dispersed pump station locations.

Q: What warranty and after-sales support do you provide for water sector installations?

A: 12 months warranty from project acceptance, with 5-year latent defect coverage. 24/7 remote technical support and spare parts at non-premium pricing are standard. On-site technical support can be arranged for international projects.

Q: What documentation can you provide for World Bank / African Development Bank-funded or IWPP project technical review?

A: Full documentation package including IEC type test reports, routine test certificates, FAT protocols, single-line diagrams, equipment layout drawings, protection relay coordination sheets, and multilingual technical manuals. Third-party inspection (SGS, BV, TÜV) can be arranged on request.

 

Request a Technical Proposal & Quote Within 24–48 Hours

 

 

page-1200-675

Our engineering team is ready to review your single-line diagrams, equipment specifications, or project technical requirements - whether your project involves a new desalination plant main substation, a municipal water treatment distribution upgrade, or corrosion-rated switchgear for a wastewater lift station. Gangheng Electric delivers IEC-compliant MV/LV switchgear with committed lead times and complete project documentation support.

Contact Us