Selection Guide
How To Use This Selection Guide
1. Confirm your system voltage
Determine whether your project operates on a 10kV or 35kV distribution system.

2. Choose your structural type
Decide between withdrawable (truck-type), fixed, or ring main unit configurations based on maintenance and operational requirements.

3. Check circuit breaker compatibility
Confirm whether your project specifies domestic vacuum breakers or imported SF₆ breakers.

4. Review the model's product page
Confirm outline dimensions, primary wiring scheme, and technical parameters against your single-line diagram.

5. Contact our engineering team for non-standard requirements
Custom busbar ratings, protection relay configurations, and panel quantities are available with no minimum order.

Types Of High Voltage Switchgear By Voltage Class
12kV (10kV System)
Suitable for utility substations, industrial and mining enterprises, high-rise buildings, and generating station auxiliaries operating on a 3-phase AC 50Hz, 10kV distribution network.

KYN28A-12 Armored Drawout AC Metal-Clad Switchgear
A withdrawable armored switchgear for 3–10kV three-phase AC single busbar systems, rated up to 3150A with short-circuit breaking current up to 40kA.

XGND-12 Box-Type Fixed AC Metal Switchgear
A fixed-type metal enclosed switchgear for 3–12kV systems, compliant with IEC 62271-200.

XGN66-12(Z) Fixed Metal Enclosed Switchgear
A 12kV indoor fixed switchgear cabinet built with a vacuum circuit breaker for three-phase AC 50Hz distribution.

GG1A-12(F) Fixed Error-Prevention High-Voltage Switchgear Cabinet
A fixed-type switchgear for 3–10kV systems with five-prevention anti-misoperation interlocking.
HXGN17-12(F/F.R) Box-Type Fixed Ring Main High-Voltage Switchgear Cabinet
A compact ring main unit for 12kV ring distribution, terminal distribution, and industrial power supply networks.

40.5kV (35kV System)
Suitable for generating stations, utility substations, industrial distribution rooms, and renewable energy (wind/PV/storage) interconnection projects operating on a 3-phase AC 50Hz, 35kV distribution network.

An armored, metal-clad, withdrawable switchgear rated 40.5kV, compatible with domestic ZN85-40.5 vacuum breakers as well as Schneider SF-series and Alstom FP-series SF₆ breakers. Rated up to 2000A with short-circuit breaking current up to 31.5kA.

A fixed-structure switchgear for 25–40.5kV single busbar and single busbar with bypass configurations.

An interval-type drawout switchgear rated 25–40.5kV/2000A, supporting seven truck types for complex substation configurations.

A handcart-type switchgear for 25–40.5kV power systems, customizable for industrial and utility applications.

KYN10-40.5 Armored Drawout AC Metal-Clad Switchgear
An armored drawer-type switchgear rated at 40.5kV for power plants, substations, and industrial applications.
Structure Type Comparison
| Comparison | Withdrawable (Truck-Type) | Fixed-Type | Ring Main Unit (RMU) |
|---|---|---|---|
| Representative Models | KYN28A-12, KYN61-40.5 | XGND-12, XGN17-40.5, GG1A-12(F) | HXGN17-12(F/F.R) |
| Maintenance Method | Breaker truck racks out to test/isolated position - no busbar de-energization | Requires full panel de-energization for maintenance | Load switch operation, simplified maintenance |
| Best Suited For | High-frequency switching, continuous supply requirements | Standard distribution, cost-sensitive projects | Ring/terminal distribution, compact substations |
| Relative Cost | Higher | Lower | Moderate |
For a detailed comparison of withdrawable versus fixed-type 35kV switchgear selection criteria, see our technical guide: Truck Type Switchgear vs Fixed Type - A 35kV Project Buyer's Decision Guide.
Key Technical Parameters To Check Before Ordering
01 - System Voltage & Rated Current
Confirm your system operates at 10kV or 35kV, and match the rated current (main busbar) to your project's load requirements.
01
02 - Short-Circuit Breaking / Withstand Current
Verify the required short-circuit breaking current (kA) and short-time withstand current against your project's fault-level calculations.
02
03 - Circuit Breaker Brand Compatibility
Confirm whether domestic vacuum circuit breakers (ZN63A-12, ZN85-40.5) or imported SF₆ breakers (Schneider, Alstom) are specified in your project documentation.
03
04 - Primary Wiring Scheme Number
Electronic + technology solutions,complete product architecture system
04
05 - Installation Space & Civil Conditions
Check foundation dimensions, maintenance aisle clearance, and cable entry requirements against the outline dimension drawing on each model's product page.
05
Why Choose GangHeng High Voltage Switchgear
Five-Prevention Safety Interlocking
All series incorporate mechanical interlocking to prevent the five most common operational errors - critical for unmanned or partially staffed substations.
Vacuum and SF₆ Breaker Compatibility
Our 40.5kV series accepts both domestic vacuum circuit breakers and imported SF₆ breakers from Schneider and Alstom, reducing procurement complexity for international EPC projects.
CNC-Precision Manufacturing
Our Jiangshan, Zhejiang facility is equipped with CNC punching machines, CNC bending machines, laser cutting machines, and copper busbar bending machines for consistent dimensional accuracy.
Certified and Grid-Qualified
Products are certified to ISO 9001, ISO 14001, OHSAS 18001, and CQC standards. GangHeng is a qualified supplier to State Grid Corporation of China and has fulfilled contracts for China Railway Construction Corporation.
No Minimum Order Requirement
We accept orders starting from a single cabinet, with delivery timelines of 30–60 days depending on order value.

Frequently Asked Questions
Q: How do I decide between 12kV and 40.5kV switchgear for my project?
A: This depends on your incoming power system voltage, not your load size. Check your utility connection agreement or single-line diagram - most distribution substations and industrial facilities operate at 10kV, while transmission-level substations, generating stations, and larger industrial parks typically operate at 35kV. If you're unsure, share your project's grid connection voltage with our engineering team for confirmation.
Q: Should I choose withdrawable or fixed-type switchgear?
A: Withdrawable (truck-type) switchgear allows breaker maintenance without de-energizing the busbar, making it the preferred choice for continuous-supply applications such as utility substations and renewable energy interconnection. Fixed-type switchgear is simpler and more cost-effective where planned outages for maintenance are acceptable. See our detailed comparison guide for a full breakdown of the decision criteria.
Q: How do I confirm the primary wiring scheme number for my order?
A: GangHeng supports over 160 primary circuit scheme combinations covering incoming, outgoing, bus-tie, metering, protection, and auxiliary configurations. If you don't have a scheme number, send us your project's single-line diagram and our engineering team will match it to the appropriate scheme before quotation.
Q: Which switchgear series is suitable for wind, solar, or energy storage projects?
A: The KYN61-40.5 is widely used in renewable energy interconnection projects, featuring harmonic resistance, anti-islanding protection, and reverse power protection functions suited to fluctuating generation profiles. Contact our engineering team with your grid connection voltage and capacity requirements for a tailored recommendation.
Q: What information do I need to provide for a custom (non-standard) configuration?
A: Please provide your system voltage, rated current, number of panels, primary wiring scheme or single-line diagram, applicable standards, and any special environmental conditions. Our engineering team will respond with a technical proposal within 24 hours.
Request A Technical Proposal

Ready to move forward with your high voltage switchgear project? Share the following information and our engineering team will respond within 24 hours:
- System voltage and rated current
- Number of panels / bays required
- Primary wiring scheme (single-line diagram if available)
- Applicable standards (GB/T, IEC, ANSI/IEEE, BS, etc.)
- Delivery location and required delivery date
Send Inquiry- Or contact us directly: zjgh2@ghswitchcabinet.com / WhatsApp +8615869060785