The YB series packaged substation is specifically designed for urban grid construction and features the following characteristics:
- Application Scope: Suitable for 50Hz, 6-10kV grids with rated capacities ranging from 50 to 1600kVA. Widely applied in various settings such as high-rise buildings, residential communities, industrial plants, mines, hotels, and more.
- Structural Features: Compact structure, high degree of integration, safe and reliable operation, easy maintenance, and aesthetically pleasing design. Small footprint, easy to move, and short production cycle.
- Intelligent Features: Can be easily equipped with intelligent systems to achieve 'four remote' distribution management via the central station's upper-level computer.


Operating Environmental Conditions
|
Altitude |
≤1000m |
|
Air temperature |
-25℃ to +40℃ |
|
Seismic intensity |
≤8 degrees |
|
Outdoor wind speed |
No more than 35m/s |
|
Installation location |
No fire or explosion hazards, no severe contamination, chemical corrosion, or intense vibration. |
Technical Specifications
• Rated Voltage: High-voltage side 12kV, low-voltage side 0.4kV; auxiliary circuit AC 110V, 220V, 380V, DC 24V, 220V.
• Transformer Rated Capacity: Covers multiple ratings from 50 to 1600kVA.
• Rated current: High-voltage side 400A to 600A, low-voltage side 100A to 2500A.
• Rated frequency: 50Hz (or 60Hz).
This packaged substation is suitable for ring network distribution systems and can also serve as a radial terminal power supply, making it an ideal choice for modern grid construction.
Rated short-time withstand current
High-voltage Switchgear:
At 12kV, the rated short-time withstand current is 16kA 2s (4s) and 20kA 2s (4s).
The rated peak withstand current is 40kA or 50kA.
The rated short-circuit closing current is 40kA or 50kA.
Low-voltage Switchgear:
At 250–315 kVA, the rated short-time withstand current is 15 kA.
At 400–800 kVA, the rated short-time withstand current is 30 kA.
For 1000 kVA and above, the actual short-circuit current applies.
Rated Peak Withstand Current
● High-voltage switchgear: At 12kV voltage, the rated peak withstand current is 40kA or 50kA.
● Low-voltage switchgear:
For capacities of 250-315kVA, the rated peak withstand current is 30kA.
For capacities of 400–800 kVA, the rated peak withstand current is 63 kA.
For capacities of 1000 kVA and above, the calculation is based on 2.2 times the rated short-time withstand current (peak).
Note: Low-voltage switchgear with capacities of 200 kVA and below are exempt from testing.
Rated short-circuit making current
At a voltage of 12kV, the rated short-circuit making current is 40kA or 50kA.
Insulation level

Transformer Parameter Specifications
Rated Noise Level:
- Oil-immersed transformers: Noise level does not exceed 50dB.
- Dry-type transformers: Noise level does not exceed 55dB.
Reactive Power Compensation Standard:
The compensation standard is 30% of the transformer capacity.
Note: This standard can be adjusted according to your requirements.
The above parameters apply only under normal operating conditions.
Under other operating conditions, the withstand voltage values must be adjusted in accordance with relevant standards.
The values in parentheses are specific standards for dry-type transformers.
The packaged substation design fully considers the diversity of power supply user needs and has the following structural features:
Modular structure
Each box-type transformer can be combined in various forms, offering flexibility and versatility.
Grid connection types
Divided into ring network type and terminal type, to meet different grid connection requirements.
Equipment layout
Includes 'mu' character-shaped structure and 'pin' character-shaped structure, with rational layout and high space utilisation.
Transformer types
Options include oil-immersed fully sealed transformers and dry-type transformers, suitable for different environments and usage conditions.
High-voltage switch selection
Options include compressed air load switches, vacuum load switches, and sulphur hexafluoride load switches.
Enclosure material:
Divided into metal enclosures and non-metal enclosures, durable and aesthetically pleasing.

Design Specifications for the Base Frame and Transformer Room of a Prefabricated Substation
Base Frame Design
The base frame of the prefabricated substation (keyword) is designed as a unified structure, closely integrated with the overall form and lifting methods. The base frame is constructed from welded channel steel and I-beam steel, ensuring structural stability. The metal frames of high and low voltage electrical equipment and all parts of the transformer housing are connected via reliable grounding conductors with a minimum cross-sectional area of no less than 30mm. Terminals connected to the grounding wire are installed around the perimeter of the base frame, allowing users to select the grounding point.
Transformer Room Structure
The transformer room features a double-layer metal structure design with an insulating layer and ventilation ducts, equipped with an automatic exhaust ventilation system. The activation and deactivation of the ventilation system are automatically controlled by a temperature monitoring device, with the temperature setpoint adjusted to 80%–90% of the allowable temperature, ensuring safe transformer operation.
Safety Protection Measures
The transformer room is equipped with doors on both sides for convenient transformer installation and maintenance. Safety isolation nets are installed inside the doors, and interlocking alarm devices are fitted on the net doors to effectively prevent personnel from accidentally entering live compartments, ensuring the safety of both equipment and personnel.


When placing an order, please provide the following key data related to the product:
Substation model
The specific model of the required substation must be clearly specified.
Transformer type and capacity
Provide detailed information on the type of transformer (e.g., dry-type, oil-immersed, etc.) and its capacity.
High-voltage room and low-voltage room wiring schemes
Provide the wiring schemes for the high-voltage room and low-voltage room, and clearly specify the types and parameters of the selected electrical components.
Enclosure Colour
Specify the required colour for the product enclosure.
Other Requirements
If there are any special requirements or customisation needs, please discuss these with the manufacturer at the time of ordering.
Note
If the project conditions exceed the above specifications, please contact us for a customised solution. We are committed to providing the best tailored solution for your unique needs.
Our story with our customers
As an important part of State Grid Jiangxi Electric Power Co., Ltd. Shangrao Power Supply Branch, State Grid Lianshan Branch selected our company as the supplier of distribution equipment such as box-type substations (keyword) for the 2020 Xinzhou Middle Road Project, and has achieved a safety record of zero accidents since its operation.




Product Certificate

Hot Tags: prefabricated substation, China prefabricated substation manufacturers, suppliers, factory, electrical padmount substation, American style transformer, box type transformer substation, prefab substation, compact transformer substation, prefabricated substation