Introduction

A 1000 kVA compact substation puts the HV switching, a 1000 kVA transformer and the LV distribution panel into a single factory-wired unit. On site, only the foundation and the cable connections remain. It takes 6–10 kV in and delivers 0.4 kV, so it suits medium-sized loads such as a production hall, a mine or a residential block.

Of the 14 capacities in the YB□-12 series (50–1600 kVA), 1000 kVA is the point where the low-voltage ratings stop being fixed values and are set from your actual short-circuit current, so a little system data from you makes the scheme more accurate. The unit belongs to Gangheng's Transformer Substation line.
It is built at our Jiangshan base in Zhejiang (5,000–20,000 m²), where CNC punching, bending, laser cutting and copper busbar bending machines are used and every product is inspected in-house.
Technical Parameters
Specifications of the YB□-12 series, which includes the 1000 kVA compact substation. Values below are series ranges unless a 1000 kVA value is stated.
Product factory real shot



| Item | Value |
|---|---|
| Capacity | 1000 kVA |
| Voltage | 12 kV / 0.4 kV |
| Current | HV 400 A or 600 A; LV 100–2500 A (series range) |
| Frequency | 50 Hz; 60 Hz version available |
| HV short-time withstand | 16 kA or 20 kA, 2 s (4 s) |
| HV peak withstand | 40 kA or 50 kA |
| LV short-time withstand | Set from the actual short-circuit current |
| LV peak withstand | 2.2 × the short-time withstand current |
| HV insulation | 75 kV lightning impulse; 42 kV for 1 min at power frequency (phase-to-earth and phase-to-phase) |
| Noise | Oil-immersed ≤ 50 dB; dry-type ≤ 55 dB |
| Reactive compensation | 30% of capacity (about 300 kvar), adjustable |
| Size, "目" layout | 2900–4500 mm wide, 1910–2450 mm deep, 3260–3680 mm high |
| Size, "品" layout | 1500–2450 mm wide, 2380–3680 mm high |
| Standards | GB/T as standard; ANSI/IEEE or BS on request |
Dimensions are series ranges. The exact size depends on the scheme you choose.
Choosing Your Configuration
Four decisions shape a 1000 kVA unit:
Grid role: ring-main (looped into the network) or terminal (end of a feeder).
Layout: "目" puts HV room, transformer room and LV room in one row; "品" stacks the HV and LV rooms beside the transformer to shorten the footprint.
Transformer: oil-immersed (fully sealed) for the lower noise figure, or dry-type.
HV load switch: compressed-air, vacuum or SF6, with an SF6-free option.
The HV and LV single-line schemes are selected from our standard set, and the exterior color is set at order.


Custom Builds
Send the transformer capacity and site drawings, and we design to them. If you only know the site, the equipment load and the result you need, our engineers will propose the scheme. Pricing usually matches the standard unit; the housing may need to be wider. There is no minimum quantity.

Where It Is Used
High-rise buildings and residential areas – small footprint
Factories and mines – direct supply at the plant or pit
Hotels, malls and parks – indoors or outdoors
Oilfields – for sites within the stated service conditions
Airports, ports and railways – relocatable
Temporary works – short build cycle

Certifications and Strength
ISO 9001 · ISO 14001 · OHSAS 18001 · CCC · Type test report. Listed on the State Grid e-commerce platform; qualified supplier of State Grid and China Southern Power Grid. 5 utility model patents.
Zhejiang Gangheng Electric has served power distribution since 2004 and is a National High-Tech Enterprise, with 50–200 staff and annual turnover of RMB 50–100 million. The Jiangshan site is under 3 km from the G3 expressway exit and under 7 km from the railway station.
Delivery And Warranty
Single units are accepted. Lead time follows order value: about 30 days at USD 300,000, 45 days at USD 700,000, 60 days at USD 1,500,000. Equipment is new and unused. Warranty runs 12 months from acceptance, followed by 5 years of hidden-defect protection, with 24/7 on-site support and spare parts at or below market price.
Frequently Asked Questions
Q: What loads is a 1000 kVA compact substation suited to?
A: Medium-sized loads on a 6–10 kV network, such as plants, mines, residential blocks and high-rise buildings.
Q: Why do you ask for short-circuit data at 1000 kVA?
A: From 1000 kVA up, the LV short-time withstand current is set from the actual short-circuit current, and the peak value is 2.2 times that. Your system data lets us match them.
Q: Oil-immersed or dry-type for 1000 kVA?
A: Both are offered. Oil-immersed units are rated ≤ 50 dB and dry-type ≤ 55 dB. Tell us the site and we will suggest one.
Q: How much reactive compensation is included?
A: By default 30% of the transformer capacity, about 300 kvar for 1000 kVA, and it can be raised or lowered.
Q: Which layout saves floor space, "目" or "品"?
A: The "品" layout has a shorter footprint, while "目" is arranged in one row. Final dimensions depend on the scheme.
Q: Can I get the drawings before ordering?
A: Yes. Send your transformer data or site details and we will return the scheme and technical data.
Hot Tags: 1000 kva compact substation, China 1000 kva compact substation manufacturers, suppliers, factory, compact transformer substation, fully enclosed substation, package transformer substation, Pad Mounted Transformer, prefabricated substation, transformer substation