Modular, draw-out low voltage switchgear for power distribution, motor control, and power compensation — built to GB7251 and JB/T9661 (IEC439/VDE0660 for MNS).

Rated Voltage: 380V / 400V / 660V
Rated Current: up to 4000A
Short-Time Withstand: up to 80kA (1s)
Peak Withstand: up to 176kA
Protection Rating: IP30 / IP40
Models Available: GCK-0.4 · MNS · GCS
Standards: GB/T standard, customizable to ANSI/IEEE or BS
No MOQ — single-unit orders accepted
23 years of manufacturing experience, factory-direct

Introduction

 

 

Draw out LV switchgear is the backbone of a low-voltage power distribution system - it takes incoming power and distributes, protects, and switches it across feeders and motor circuits, while letting maintenance staff pull out a faulty unit and swap in a spare without shutting down the whole panel. Gangheng's Draw out LV switchgear range covers three model families - GCK-0.4, MNS, and GCS - spanning 380V to 660V and up to 4000A, so buyers can match voltage class, current rating, and cabinet structure to their project rather than fitting the project to one fixed product.

These sit within Gangheng's broader [Low Voltage Switchgear] product line, alongside our fixed-type (non-draw-out) cabinets.

All units are produced at Gangheng's manufacturing base in Jiangshan, Zhejiang, on a 5,000–20,000 m² site equipped with CNC punching machines, CNC bending machines, laser cutters, and busbar bending machines, with in-house testing across the full production process.

 

Quick Spec Comparison

 

GCK-0.4

GCK Draw Out Type LV Switch Cabinet

0.4kV (400V)

Busbar: 1000 / 1600 / 2500 / 3200A

50kA (1s) / 105kA peak

GB7251, JB/T9661

Draw-out, enclosed, PC & MCC types

MNS

MNS Series Three Phase Switchgear Cabinet - Modular Complete Switchgear For Industrial Power Distribution

380V / 660V

Horizontal bus: 630–4000A; Vertical bus: 1000A

50–80kA (1s) / 105–176kA (1s, alt.) / 105–150kA peak

IEC439 (EC439), VDE 0660 Part 5, GB7251-97, JB/T9661

Draw-out, modular (E=25mm), PC & MCC

GCS

GCS Series Low Voltage Withdrawable Switchgear Cabinet

380(400)V / 660V

Horizontal bus: ≤4000A; Vertical bus (MCC): 1000A

50/80kA (1s) / 105/176kA peak

GB7251, JB/T9661

Draw-out, enclosed, modular (E=20mm)

 

 

 

 

Cabinet Configuration

 

 

 

Like Gangheng's other switchgear lines, GCK, MNS and GCS are sold as a combination of functional cabinets, not a single SKU - buyers configure a complete system from:

Incoming cabinet (overhead-line or cable incoming)

Feeder / outgoing cabinet

Tie cabinet (bus-coupler)

Motor Control Center (MCC) - both GCK and MNS offer dedicated MCC cabinets (single-face or double-face operation); GCS integrates motor control into its functional-unit sizing instead of a separate MCC line.

product-1200-800

GCS additionally standardizes functional units into five drawer sizes - 1/2 unit, 1 unit, 1+1/2 unit, 2 unit, and 3 unit (160mm module height) - so drawers of the same functional size are interchangeable across cabinets.

Main breaker type/rating is selected per project requirements; outgoing circuits are fitted with current transformers as needed.

product-900-675

 

Technical Parameters

GCK-0.4

Parameter

Value

Rated working voltage

0.4kV

Rated busbar current

1000A / 1600A / 2500A / 3200A

Rated short-time withstand current (1s)

50kA

Rated peak withstand current

105kA

Enclosure protection rating

IP30; IP40

Applicable standards

GB7251 Low-voltage switchgear and controlgear assemblies; JB/T9661 Draw-out type low-voltage switchgear assemblies

Standard configuration

Executed to GB/T national standards; can be executed to ANSI/IEEE or BS on customer request

MNS

Rated frequency

50–60Hz

Rated working voltage

380V / 660V

Rated insulation voltage

660V

Rated current

Horizontal bus: 630–4000A; Vertical bus: 1000A

Rated short-time withstand current

Horizontal bus: 50–80kA / 105–176kA; Vertical bus: 50kA/150kA

Enclosure protection rating

IP30, IP40, IP54*

Applicable standards

IEC439, VDE0660 Part 5, GB7251-97, JB/T9661; can be executed to ANSI/IEEE or BS on customer request

 

*IP54 is available but not recommended, as derating at this rating is significant. 

 

GCS

Parameter

Value

Rated main-circuit voltage

AC 380(400)V / 660V

Rated auxiliary-circuit voltage

AC 220V / 380(440)V; DC 110V / 220V

Rated frequency

50(60)Hz

Rated insulation voltage

660V (1000V)

Rated current

Horizontal bus: ≤4000A; Vertical bus (MCC): 1000A

Rated short-time withstand current (1s)

50kA / 80kA

Rated peak withstand current

105kA / 176kA

Power-frequency withstand voltage (1 min)

Main circuit: 2500V; Auxiliary circuit: 2000V

Busbar arrangement

3-phase 4-wire: A.B.C.PEN; 3-phase 5-wire: A.B.C.PE.N

Enclosure protection rating

IP30, IP40

Applicable standards

GB7251, JB/T9661; can be executed to ANSI/IEEE or BS on customer request

 

 

Full external dimension and mounting-base drawings (width/depth options per current rating) are available for each model on request.


 

 

 

product-1200-800
product-1200-800
product-1200-800
product-1200-800

Customization

 

Gangheng accepts non-standard customization as a standard part of the sales process, not an exception:

We support customized configurations. Provide us with your transformer capacity and site drawings and our team will design a matching solution; if exact parameters aren't available, tell us the installation site, the connected equipment load, and the functional outcome you need, and our engineering team will propose a custom design. In most cases, custom configurations are priced the same as standard ones (dimensions may widen depending on the configuration). There is no minimum order quantity - we can deliver a single unit.

Request Custom Solution

 

 

 

 

Applications

 

 

  • Power systems (generation, transmission, and distribution)
  • Power plants and substations
  • Petrochemical industry
  • Metallurgy and steel industry
  • Light industry and textile industry
  • Factories and mines

  • Residential areas and high-rise buildings

 

 

 

Quality Certifications

 

product-1200-800

ISO9001 (Quality Management System)

ISO14001 (Environmental Management System)

OHSAS18001 (Occupational Health & Safety Management System)

CQC Certification

Type test reports (HV switchgear line)

Patents: 5 utility model patents

Listed on the State Grid e-commerce procurement platform; a qualified supplier to State Grid and China Southern Power Grid

 

 

Products Description

 

product-2344-1563

Manufacturing base: Jiangshan, Zhejiang - under 3km from the G3 Beijing–Taipei Expressway Jiangshan South exit, under 7km from Jiangshan Railway Station, served by National Highway 205 and the Zhejiang–Jiangxi Railway

Key equipment: CNC punching machines, CNC bending machines, laser cutters, busbar bending machines, and a full range of testing equipment

Scale: 50–200 employees, 5,000–20,000 m² site, annual revenue RMB 50M–100M

23 years in the power distribution equipment industry (founded 2004)

 

 

Delivery & Trade Terms

 

 

 

 No minimum order quantity - single-unit orders accepted

 

 Lead time scales with order value: ~$300K orders in 30 days, ~$700K orders in 45 days, ~$1.5M orders in 60 days (or state as "lead time varies with order scale - contact us for a quote" if exact tiers shouldn't be public)

 

 All equipment delivered is brand new, unused product

 

⬅GangHeng Electric Ships Switchgear Units To Myanmar

 

Warranty & After-Sales

 

12 months free warranty from acceptance

5 years of latent-defect protection after the warranty period ends

24/7 on-site support; spare parts priced at or below market rate

Technical documentation and training provided

Responsive handling of defects, missing parts, and quality inspection during installation and commissioning

 

 

 

Frequently Asked Questions

 

Q: What voltage and current range does GCK-0.4 / MNS / GCS Draw out LV switchgear cover?

A: GCK-0.4 is rated 0.4kV with busbar currents of 1000A, 1600A, 2500A or 3200A. MNS covers 380V and 660V, with horizontal-bus current from 630A to 4000A and a 1000A vertical bus. GCS covers 380(400)V and 660V, with horizontal-bus current up to 4000A and a 1000A vertical (MCC) bus. See the comparison table in Section 2 and the full parameter tables in Section 4.

Q: Can GCK-0.4 / MNS / GCS be customized to my transformer or site parameters?

A: Yes. Send us your transformer capacity and site drawings and we'll design a matching solution; if you don't have exact parameters, tell us the installation site, the connected equipment load, and the functional outcome you need, and our engineering team will propose a custom design. Customized configurations are priced the same as standard ones in most cases (dimensions may widen depending on the configuration), and there's no minimum order quantity.

Q: Which standards does each model meet - can it be supplied to ANSI/IEEE or BS requirements?

A: GCK-0.4 and GCS are built to GB7251 and JB/T9661. MNS additionally complies with IEC439 and VDE0660 Part 5. All three can be executed to ANSI/IEEE or BS standards on customer request - standard configuration follows GB/T national standards, with international standards available as a custom option.

Q: Is there a minimum order quantity?

A: No. We accept single-unit orders - there's no MOQ on any of these three lines.

Q: What is the lead time?

A: Lead time scales with order value: roughly 30 days for orders around $300K, 45 days around $700K, and 60 days around $1.5M. Contact us with your order scale for a specific quote.

Q: What does the warranty cover, and what happens after it expires?

A: 12 months of free warranty from acceptance, followed by 5 years of latent-defect protection after the warranty period ends. We also provide 24/7 on-site support, spare parts priced at or below market rate, technical documentation and training, and responsive handling of defects or missing parts during installation and commissioning.

Q: Can drawings and technical documentation be provided before I place an order?

A: Yes - for GCK-0.4 we'll need your one-line circuit layout, secondary circuit schematic (with scheme number if using a standard scheme), and switchgear arrangement plan; for MNS, the main-circuit single-line diagram, schematic, and full per-cabinet equipment specification; for GCS, the full model number with circuit scheme codes, main and auxiliary circuit diagrams, and the in-cabinet component list. We can review and quote based on whichever of these you're able to share.

 

 

product-1200-960

Whether you need to see the exact cabinet configuration for your current rating, or just want a number to work with - we've got you covered.

 

Download Main Circuit Diagram to see the detailed configuration, or Get a Quote and tell us your requirements - we'll get back to you with a solution and pricing within 24 hours.

Hot Tags: draw out lv switchgear, China draw out lv switchgear manufacturers, suppliers, factory, Distribution Box, Electrical distribution box, gcs type low voltage drawout complete switchgear, switchboard and switchgear, switchgear and structurals, underground distribution switchgear

Send Inquiry